Home
DataTaker
Global Water
Elpro
Pace
Oxyguard
HandyWave
Wavecom
Eagle
Hanna
Digitron
Testo
Huger
TPS
Solar Panels
Wind Turbines
Grant Squirrel
Special Offers
Contact Us
News
e-mail me

FC200
  FC200 OPEN CHANNEL FLOW MONITOR
Measure and Totalize Flows in Open Channels

Open Channel Flow Monitor

FEATURES:
  • Digital LCD screen
  • Easy-to-use interface with user selectable flow tables
  • Highly accurate depth probe
  • Output signal for recorders or displays
  • Sampler triggering output
  • Water resistant enclosure
Product Description
Global Water's Open Channel Flow Monitor is reliable and accurate for measuring and totalizing open channel flows for all flumes and weirs, as well as for any gravity-type open-channel flow application.  The flow meter measures water depth with Global Water's highly accurate pressure transducer, and the unit's electronic circuitry instantly calculates and displays water flow and totalizer values for any depth-to-flow relationship in any engineering units.  The Open Channel Flow Monitor is easy to set up in the field using a unique four-button programming system.

Open Channel Flows
For any open channel that is free flowing, there is a specific relationship between depth of water and flow rate.  Whenever a given depth occurs, there will always be the same flow.  Therefore, if the flow rate is known for each depth, a depth-to-flow relationship can be constructed.  The Open Channel Flow Monitor is pre-programmed with depth-to-flow relationship tables.  When the user digitally selects the correct depth-to-flow relationship for an application, the Open Channel Flow Monitor's LCD screen automatically displays accurate flow rate measurements for any depth that is reached.  This water flow is averaged over time to display total flow.

When using a primary device to measure flow, such as a measuring flume or weir, there is a mathematical relationship between depth and flow.  When measuring flow in a channel that does not have a primary device, the depth-to-flow table can be constructed by measuring the flow at several different depths, using Global Water's Flow Probe.

Depth Measurement
Global Water's Open Channel Flow Monitor measures flow depth with the highly-accurate
WL400 Water Level Sensor, which is a fully submersible water level sensor constructed of stainless steel.  The standard level range is from 0 to 3' of water, which provides for accurate flow measurements even with depth change is as small as a fraction of an inch.  The pressure transducer is mounted slightly below the "zero" flow depth of the channel, upstream from the throat of the flume or weir.  For open channels with no primary device, the sensor is mounted below the lowest expected water depth.  The water level sensor has a 2-wire 4-20 mA signal, so the flow computer can be mounted several hundred feet away, if required.  The sensor and computer can be connected with standard, twisted-pair signal wire.

Display and Outputs
The Open Channel Flow Monitor displays flow rate on a large 6-digit LCD screen.  The totalized output is shown on a second LCD display.  The display reads in user-defined units of flow, including mgd, csf, gpm, m3s.

The Flow Monitor also produces an analog 4-20 mA output signal that is proportional to flow.  This can be used for chart recorders, dataloggers, or as an input to telemetry or process control systems.  In addition, the meter has a flow-proportional output signal for triggering water samplers.

Digital Flow Computer
The Global Water Open Channel Flow Monitor has powerful internal electronic circuitry that calculates and totalizes flow.  Desired engineering units and depth-flow relationships (from over 20 pre-defined tables) can easily be selected using the unit's four front panel push buttons.  User programming does not require the unit's enclosure to be opened.  The unit's manual includes programming information, including depth-to-flow tables for all standard flumes and weirs.

Enclosure
The enclosure is made of weatherproof injection molded plastic.  It is suitable for use in a wide variety of environments.  The enclosure can be wall-mounted and fitted with conduit for sensor and power connections, if required.

Specifications

Rate Display: 6 digit + decimal place, LCD
Totalizer Display: 6 digit + decimal place, LCD
Accuracy: Pressure transducer: +0.2% FS, Flow Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units
Enclosure: 4 3/4" W x 8" H x 3" D, NEMA 4X (IP67)
Power: 120 VAC to 240 VAC, optional: Battery powered (Must be specified at time of ordering)

Pre-defined Tables
Parshall: 1", 2", 3", 6", 9", 12"
Palmer-Bowlus (4D): 4", 6", 8", 10", 12", 15"
Weir: 45° V notch, 90° V notch, 1' rectangular, 2' rectangular
H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°

Custom Table
You must provide Global Water with a depth to flow equation or look up table at time of order.  Please allow for longer lead times.

Options
FC200 Open Channel Flow Monitor
0-3' Depth Sensor.  Please specify flume/weir type when placing order.
Battery Option
Includes Heavy-Duty Hazardous Environment Enclosure
 
RELATED PRODUCTS
GL400-1-1 Datalogger
Two-channel datalogger with heavy-duty hazardous environment enclosure.
 
FSS Flow Sampling System
A unique combination of products that makes monitoring, sampling, and recording stormwater or industrial discharge water flows easy.

 




[ First ] [ Prev ] [ Next ] [ Last ]



|Home| |DataTaker| |Global Water | |Elpro| |Pace| |Oxyguard| |HandyWave| |Wavecom| |Eagle| |Hanna| |Digitron| |Testo| |Huger| |TPS| |Solar Panels| |Wind Turbines| |Grant Squirrel| |Special Offers| |Contact Us| |News|